Home Industrial Solutions Process Instrumentation Signal Conditioners
|
XJ2 (2 Wire) Universal Input Single Transmitter
XJ22 (2 Wire) Universal Input Dual Transmitter
|
|
|
|
XJ2 (Single Transmitter)
|
XJ22 (Dual Transmitter)
|
| Features: |
Features: |
Field Programmable Bi-Polar Input Ranges.
Input Types:
- mV, V & mA.
- RTD Pt100.
- Differential RTD.
- Thermocouple (T/C).
- Bridge \ Strain Guage.
- Potentiometer.
- Resistance.
Input to Output Isolation 2.0kV.
High Accuracy 0.1%
Reverse Polarity Protected.
LED Indication of Current Loop (CL).
Compact DIN Rail Mount Enclosure.
Available with One or Two Transmitters per Enclosure.
Available Standard or Special Calibration.
Easy Install.
Low Cost. |
Field Programmable Bi-Polar Input Ranges.
Input Types:
- mV, V & mA.
- RTD Pt100.
- Differential RTD.
- Thermocouple (T/C).
- Bridge \ Strain Guage.
- Potentiometer.
- Resistance.
Input to Output Isolation 2.0kV.
High Accuracy 0.1%
Reverse Polarity Protected.
LED Indication of Current Loop (CL).
Compact DIN Rail Mount Enclosure.
Available with One or Two Transmitters per Enclosure.
Available Standard or Special Calibration.
Easy Install.
Low Cost. |
|
XJ-2 & XJ-22 Specifications:
|
|
|
|
|
|
| Ordering Information: |
|
|
|
| |
|
|
|
| LPI-CT (AC Current Transmitter) |
 |
|
Features:
- Field Programmable 1Aac or 5Aac.
- Mains Isolated.
- High Accuracy.
- Reverse Polarity Protected.
- LED Indication of Current Loop (CL).
- Compact DIN Rail Mount Enclosure.
- 40~200mV Output Test Signal.
- Easy to Install.
- Low Cost.
- Wide P/S Range.
- Available with One or Two Transmitters per Enclosure.
|
| Ordering Information: |
 |
| IN-CLL (Current Loop Limiter) |
 |
|
Features:
- Compact DIN Rail Mount Enclosure.
- High Accuracy.
- Low Cost.
- Easy to Install.
- Reverse Polarity Protection.
- Setpoint Adjustment Externally Accessible (By 20 turn potentiometer).
|
|
Description:
The IN-CLL is a loop powered transmitter designed to limit the maximum current that can flow in a 0~20mA or 4~20mA loop. Requiring only 3V (equivalent to 150Ω @ 20mA) out of the loop supply. The setpoint can be adjusted anywhere from 1 to 22mA, has excellent cut-off with no effect on calibration.
|
| Ordering Information: |
 |
| LPI-D (DC Transmitter) |
 |
|
Features:
- Field Programmable Bi-Polar Input ranges.
- Isolated Input to Output 2.0kV.
- High Accuracy.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
|
XI 4~20mA Isolator Series
XI-L Loop Powered Isolators
|
| Isolating 4~20mA Input to 4~20mA Output Loop Powered Transmitter |
 |
Features:
- Input to Output Isolation 1kV.
- High Accuracy 0.1%.
- Reverse Polarity Protected.
- Compact DIN Rail Mount Enclosure.
- Available With 1, 2 or 4 Transmitters per Enclosure.
- Easy to Install.
- Low Cost.
|
 |
|
Ordering Information:
|
XI-L1
XI-L2
XI-L4 |
One Unit per Enclosure.
Two Units per Enclosure.
Four Units per Enclosure. |
|
|
XI 4~20mA Isolator Series
XI-P Input Powered Isolators
|
| 4~20mA Input Powered to 4~20mA Output Isolation Transmitter |
 |
|
Features:
- No Power Supply Needed - Input Powers Transmitter.
- Ideal for isolating a typical 4~20mA loop.
- Input to Output Isolation 1kV.
- High Accuracy.
- Reverse Polarity Protected.
- Compact DIN Rail Mount Enclosure.
- Available With 1, 2 or 4 Transmitters per Enclosure.
- Easy to Install.
- Low Cost.
|
 |
|
Ordering Information:
|
XI-P1
XI-P2
XI-P4 |
One Unit per Enclosure.
Two Units per Enclosure.
Four Units per Enclosure. |
|
| PI-F (Programmable Isolating Frequency Transmitter) |
 |
|
Features:
- Field Programmable Input and Output Ranges.
- Bi-Polar Output Ranges.
- Fast Response Time, Allowing Accurate Control.
- Impedance Matching on Input.
- Contact Closure Selection.
- Crystal Locked Period Measurement.
- Input to Output Isolation 1.0kV.
- High Accuracy 0.1%
- Universal AC/DC Power Supply.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
|
| Ordering Information: |
 |
| LPI-F (Frequency Transmitter) |
|
LPI-F-D LPI-F-E
|
|
Features:
- Field Programmable Input Ranges.
- Isolated Input to Output 2.0kV.
- Impedance Matching on Input.
- Crystal Locked F-V.
- Selectable Damping.
- High Accuracy 0.1%.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount or IP67 Water Resistant Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| TWN-FO (TWI-FO) (PLC Input Transmitter) |
 |
|
Features:
- PLC Interface. Converts 4~20mA Signal into a Frequency for Direct Conversion into a Digital Input.
- Isolated Input to Output 1.6kV for TWI-FO.
- High Accuracy.
- LED Indication of Frequency Output.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Reverse Polarity Protection.
- Externally Accessible Span and Zero Adjustments.
|
|
Description:
The TWI-FO and TWN-FO are designed as a low cost alternative to expensive A/D cards on PLCs, computers and data acquisition systems. The TWI-FO and TWN-FO convert and analogue signal into a linear, frequency output signal, with a 50:50 mark space ratio. Ideally designed to be used with a PLC to convert a 4~20mA signal into a 10~1010Hz frequency, (Other calibrations available.) allowing direct connection into a digital input on a PLC (Use with interupts.) and powered by the PLC's 24Vdc power supply. Refer to 'Connection Diagrams' for the multiple connection variations.
Note: The converson from TWN-FO to TWI-FO is easily achieved by the removal of two internal links. Refer to ranging information.
|
| Ordering Information: |
 |
|
Specifications:
|
| TWN-FF (TWI-FF) (PLC Input Transmitter) |
 |
|
Features:
- Trimec DP490 to PLC Interface.
- Frequency I/P Divided to a Frequency Output.
- LED Indication of Frequency Output.
- Isolated Input to Output 1.6kV for TWI-FF.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Reverse Polarity Protection.
- Externally Accessible Span and Zero Adjustments.
|
|
Description:
The TWN-FF & TWI-FF are designed as an interface between a Trimec DP490 Flow Transducer and a PLC. The TWN-FF & TWI-FF divide the frequency of the pulses from a DP490 to an output frequency a PLC can Register without missing counts. For example if a DP490 is measuring flow that results in an output frequency of 40Hz, and the maximum PLC input frequency is 10Hz, the TWN-FF & TWI-FF would be ordered with a division factor of four.
The TWN-FF & TWI-FF can be powered by the PLCs 24Vdc power supply. The output is a 50:50 mark space ratio, and can be directly connected into most PLC digital inputs.
|
| Ordering Information: |
 |
|
Specifications:
| Input |
-Maximum Range |
100kHz. (5V p-p input). |
| |
-Trigger Level |
2.5Vdc. |
| |
-Amplitude |
5~30Vdc Squarewave. |
| |
-Maximum Range |
5kHz. |
| Output |
-Function |
Squarewave Output; 50:50 Mark \ Space Ratio. |
| -Sink/Source |
-Amplitude |
(Power Supply) -2V. (No Load.) |
| |
-Load |
Limited to Sink \ Source 100mA @ 24Vdc. (50mA @ 12Vdc.) |
| |
|
Maximum Load = 100mA @ 24Vdc. |
| |
|
Suitable for most optocoupler inputs. |
| -Open Collector |
|
30Vdc, 100mA Max. |
| |
|
Other variations available on request. |
| Isolation Test Voltage |
(TWI-FF Only) |
Input to Output 1600Vdc for 1min. |
| Power Supply |
|
11~28Vdc. |
| Current Usage |
|
15mA (No Output Load.) |
| EMC Compliances |
|
Emissions EN55022-A, Immunity EN 50082-1, <1% Effect FSO Typical. |
| Operating Temperature |
|
0~70C. |
| Storage Temperature |
|
-20~80C |
| Operating Humidity |
|
5~85%RH Max. Non-condensing. |
| Construction |
|
Polyamide Thermoplastic Rail Mount. |
| Dimensions |
|
L=79mm, W=22.5mm, H=85mm. |
|
PI-M (Programmable Isolating
Maths Function Transmitter) |
 |
|
Features:
- Field Programmable Input and Output Ranges.
- 32 Predefined Math Functions.
- 12 Bit Resolution. (0.025%)
- Isolated Input to Output 1.6kV.
- High Accuracy to 0.1%
- Universal AC/DC Power Supply.
- Compact DIN Rail Mount Enclosure.
- 120 Point User Definable Curve Fitting
|
| Ordering Information: |
 |
| LPI-P (Potentiometer Transmitter) |
 |
|
Features:
- Field Programmable Input Ranges.
- Isolated Input to Output 2.0kV.
- High Accuracy.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Selectable 3 Second Input Damping.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| LPN-P (Potentiometer Transmitter) |
 |
|
Features:
- Field Programmable Input Ranges.
- High Accuracy.
- 40~200mv Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
|
Ordering Information:
| LPN-P |
Standard 0~100% Input.
Programmable Input Range Calibration. |
|
| LPI-K (Resistance Transmitter) |
 |
|
Features:
- Field Programmable Input Ranges.
- High Accuracy.
- Linear with Temperature.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| LPI-R (RTD Transmitter) |
 |
|
Features:
- Pt100 RTD Standard Input.
- Isolated Input to Output 2.0kV.
- Field Programmable Input Ranges. (LPI-R-P)
- High Accuracy.
- Linear With Temperature.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| LPI-N (Differential RTD Transmitter) |
 |
|
Features:
- Differential Pt100 RTD Standard Output
- Isolated Input to Output 2.0kV.
- Field Programmable Input Ranges.
- High Accuracy.
- Linear with Temperature.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| LPN-R (RTD Transmitter) |
 |
|
Features:
- Field Programmable.
- Pt100 RTD Standard Input.
- High Accuracy 0.1%.
- Linear With Temperature.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current (CL).
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
- Available With One or Two Transmitters per Enclosure.
|
| Ordering Information: |
 |
| LPI-T (Thermocouple Transmitter) |
 |
|
Features:
- Available for Types J, K, N, R, S, T.
- Field Programmable Input Ranges.
- Output Linear With Temperature.
- Internal Cold Junction Compensation.
- Isolated Input to Output 2.0kV
- High Accuracy.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
| LPI-B (2 Wire Bridge Transmitter) |
 |
|
Features:
- Field Programmable Bi-Polar Input Ranges.
- Isolated Input to Output 2.0kVDC.
- High Accuracy.
- 40~200mV Output Test Signal.
- LED Indication of Loop Current.
- Selectable 3 Second Input Damping.
- Low Cost.
- Easy to Install.
- Compact DIN Rail Mount Enclosure.
- Available Standard or Special Calibration.
- Reverse Polarity Protection.
|
| Ordering Information: |
 |
PI-S (Programmable Isolating
Dual Set Point Alarm Unit) |
 |
|
Features:
- Field Programmable Input Ranges.
- Isolated Input to Output 1.6kV.
- High Accuracy.
- Universal AC/DC Power Supply.
- 0~100% Alarm Set Point Range.
- Dual Relay or SSR Drive Outputs.
- LED Indication of Relay Status.
- N.O. \ N.C. Selectable Contacts.
- 0.2~30sec Adjustable Delay.
- High, Low, Window & Differential Selectable Alarms.
|
| Ordering Information: |
 |
|
|