Home Industrial Solutions Data Loggers/Recorders Temperature
| Mini Portable Data Loggers: |
 |
| MicroToT - Small Single Temperature Logger |
|
The microToT is a single channel temperature logger. The two main features that distinguish this logger are its cost and size. The microToT has been designed for users who require a small, simple Temperature logger at low cost.
The microToT can be controlled and interrogated over phone lines using a standard modem link. The Logger can dial a Pocket Pager when Alarm Conditions occur.
|
|
 |
| SafeT - Dual Channel Data Logger |
|
The SafeT is an economic Dual Channel Data Logger with sophisticated Operational, Alarm and Communications capabilities.
It features an Internal Temperature Channel and an External Channel that can be used with a range of sensors for measuring Temperature, Humidity, Pressure, Light, Wind Direction, Voltage and Current.
|
|
HR Series:
|
|
Description:
HR Series loggers are small, single and multi channel loggers housed in a rugged 20mm diameter 304 stainless steel case. The logger contains an integral internal temperature sensor which is logged separately to its main function.
High accuracy and large storage capacity make the HR series ideal for most industrial and commercial applications.
The HR loggers can also be left connected permanently to the PC for instantaneous viewing of the data. All data is real time (time and date stamped). All TruTrack loggers will connect directly to a modem for remote down loading of data and can also send SMS messages on an alarm condition.
|
Features:
- 304 Stainless Steel Case.
- 1 to 5 year battery life depending on usage, factory replaceable. Data is retained in the event of battery failure.
- High Accuracy 12 Bit.
- Up to 64,000 readings can be stored (except as stated below).
- User selectable sampling rate from 1 second to 10 hours in 1 second increments.
- Operating range of -30°C to +70°C (-22°F to +158°F).
- DLC3USB [USB] or DLC3 [RS232] download cable is used with all HR Series loggers.
|
 |
| T-HR - Single Temperature |
|
The T-HR is a small single channel high resolution (12 Bit) Temperature data logger.
Now with HUGE storage capacity of over 500,000 samples (mark 4)!
|
|
 |
| Tc-HR - Thermocouple Temperature |
|
The Tc-HR is a small Two Channel High Resolution (12 bit) Temperature data logger.
The logger connects to an external Thermocouple probe and also has an internal temperature sensor. The logger accepts Type J,K,N,R and T thermocouple probes.
Please Note: Tc-HR data loggers are not supplied with a thermocouple probe. These can be ordered seperately from Intech Instruments if required.
|
|
 |
| Pt-HR - External Pt100 Temperature |
|
The Pt-HR is a small Two Channel High Resolution (12 bit) Temperature data logger.
The logger connects to an external Pt-100 sensor. It also has an internal temperature sensor.
Please Note: Pt-HR data loggers are not supplied with a Pt100 probe. These can be ordered separately from Intech Instruments if required.
|
|
| LCD Series: |
|
Description:
LCD Series loggers are handheld, high resolution (16 bit) data loggers with a liquid crystal display. The LCD display means that realtime readings can be viewed without having to connect the logger to a computer.
The logger contains an integral internal temperature sensor which can be logged separately to its main function.
High accuracy and large storage capacity make the LCD series ideal for most industrial and commercial applications.
All TruTrack loggers will connect directly to a modem for remote down loading of data and can also send SMS messages on an alarm condition.
|
Features:
- HUGE storage capacity of over 500,000 samples!
- High Accuracy 16 Bit.
- 1 to 5 year battery life depending on usage, user replaceable. Data is retained in the event of battery failure. Battery status monitor on LCD display and in OmniLog software.
- User selectable sampling rate from 1 second to 10 hours in 1 second increments.
- Operating range of -20°C to +70°C (-4°F to +158°F).
- DLC8USB [USB] or DLC8 [RS232] download cable is used with all LCD Series loggers.
- LCD series loggers are designed for indoor use (IP40) but can be supplied with an optional IP66 Weather Proof Enclosure for outdoor use.
|
|
|
| Tc-LCD - Thermocouple |
|
The Tc-LCD is a handheld two channel high resolution (16 bit) temperature data logger with a liquid crystal display. The logger connects to an external thermocouple probe and also has an internal temperature sensor.
The logger accepts Type J,K,N,R and T thermocouple probes (factory set to type K).
The display shows ambient temperature, thermocouple temperature, battery voltage, logger and alarm status.
The logger uses the standard NIST (National Institute of Standards and Technology) equations to calculate, display and log temperatures from the various thermocouple probe types.
Please Note: Tc-LCD data loggers are not supplied with a thermocouple probe. These can be ordered seperartely from Intech Instruments if required.
|
|
|
|
|
Thermocron
|
|
The Thermocron is a low cost, robust devise that records temperature. The thermocron will record up to 2048 readings with 0.5 degree resolution and time stamp.
|
|
 |
|
Features::
Stainless steel construcion.
17.35mm diameter, 5.89mm thick.
models covering -20 to 85 degrees C.
2048 consecutive readings. |
|
|