Home arrow Industrial Solutions arrow SCADA Systems arrow I/O Field Stations
I/O Field Stations PDF Print E-mail
2100-M (Analogue Input Multiplexer) 

 IN-ICM - Isolating Clock Module for 2100-M

2100-m-pict

 Please Note: Modbus Protocols are NOT available with the 2100-M
If you require a multiplexer with Modbus Protocols please view the 2100-A16.
 

Features:

  • 16 Channel Multiplexer
  • Field Programmable Inputs
  • Field Programmable Output
  • Input Types Available:
    • - MilliAmp;
    • - Pt100 RTD;
    • - Volts and Millivolts;
  • Clock/Reset Channel Selection, or Binary Channel Selection.
  • High Accuracy 0.1%
  • Compact DIN Rail Mount Enclosure
  • Easy to Install
  • Low Cost Expansion for PLCs
  • Solid State Switches for Reliability
 

Description:

The 2100-M is used extensively in industrial plants, with proven reliability and accuracy. It comes complete and ready to operate in a compact DIN rail mount enclosure.

The 2100-M (previously the EXPO-3) can multiplex up to 16 analogue inputs, into one input of a PLC or a Data Logging System. It uses solid state switches, making it extremely reliable and durable.

The 2100-M is widely used to expand up inputs on the 2100-A 16 and 2100-A4, plus give economic easy accurate analogue input expansion on a PLC.

The PLC only requires two digital outputs and one analogue input to select and receive data from the 2100-M. For each additional 2100-M added to the system, only one more analogue input is required.
(The typical fan-out for most PLC's is up to eight 2100-M's)

The 2100-M-I, the 2100-M-R and the 2100-M-V are on board input span programmable. The output can be configured to a selection of industry standard output signals.

 Ordering Information:

2100-m-ordering

 Note: Power supply H is field selectable for M; and M for H. Power supply L must be ordered separately.
 
Specifications:
Analogue Input Multiplexer: 16 Single ended inputs
Each Multiplexer is span programmable with in the specified input type as below:
2100-M-R=RTD Pt100 (-200~600°C) (-330~1100°F)
2100-M-I=4~20 / 0~20mA
2100-M-V=mV & V (-25~500mV and 0~10V DC)
2100-M-T=Thermocouple (-100~1700°C) (-150~3000°F)
Note 1:Minimum Thermocouple span = 200°C (400°F)
Note 2:2100-M-T requires a PI-T transmitter
Accuracy: <± 0.1% FSO Typical
Ambient Drift: < 00.1% / °C FSO Typical
Isolation on clock
& reset:
1kV AC/DC for 1 min
Operating Temperature: 0~60°C
Storage Temperature: -20~80°C
Operating Humidity: 5~85% RH Max. Non condensing
Housing: DIN & EN Rail mount
L = 195mm, W = 120mm, H=70mm
Power Supply: -H
-M
-L

85~264V ac/dc; 50/60 Hz; 10VA
23~90V dc; 10VA
10~28Vac/dc; 50/60Hz; 10VA

Note: Power supply H is field selectable for M; and M for H. Power supply L must be ordered separately.

 2100-m-con

 

 

 

 